Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Chinese Journal of Radiological Medicine and Protection ; 40(4):268-272, 2020.
Article in Chinese | EMBASE | ID: covidwho-2282124

ABSTRACT

Objective: To explore the clinical practice of delivering radiotherapy during the outbreak of 2019 novel coronavirus disease(COVID-19). Method(s): During this epidemic period, available method including but not limited to: strict disinfection, body temperature monitoring and staff training of relevant knowledge, were used to ensure the safety of radiotherapy treatment. Statistical analysis was performed to study the relevant data including proportion of patients receiving radiotherapy for different purposes, time from scanning to the first time of radiation delivery and degree of satisfaction in the view of staffs and patients, respectively. Result(s): A total of 60 patients received radiation therapy in the department of radiotherapy of Zhejiang Provincial People's Hospital (2020-02-11). Compared with the same period in 2019 (after the Spring Festival), the total number of patients receiving radiotherapy was decreased from 72 to 60(83.3%). Among them, the number of patients receiving palliative radiation therapy decreased significantly, while the proportion of radical, preoperative and/or postoperative radiotherapy/radiochemotherapy did not significantly decrease. There was significant difference between two years (chi2=6.967, P<0.05). The median time for newly admitted patients to receive radiotherapy was two days, which was not significantly longer than the interval in 2019 (P>0.05). Staff and patients were generally satisfied with the current prevention measures. Conclusion(s): Using a variety of prevention and control method, and taking full account of medical safety and patient benefits, radiation-related activities can be carried out during the epidemic.Copyright © 2020 by the Chinese Medical Association.

2.
Pathol Int ; 73(3): 120-126, 2023 Mar.
Article in English | MEDLINE | ID: covidwho-2193181

ABSTRACT

During the coronavirus disease 2019 (COVID-19) pandemic, autopsies have provided valuable insights into the pathogenesis of COVID-19. The precise effect of this pandemic on autopsy procedures in Japan, especially in instances unrelated to COVID-19, has not yet been established. Therefore, we conducted a questionnaire survey from December 2020 to January 2021 regarding the status of pathological autopsy practices in Japan during the first year of the COVID-19 pandemic. The questionnaire was sent to 678 medical facilities with pathologists, of which 227 responded. In cases where a confirmed diagnosis of COVID-19 was not made at the time of autopsy, many facilities counted them as suspected COVID-19 cases if pneumonia was suspected clinically. At around half of the sites, autopsies were prohibited for suspected COVID-19 cases. In addition, the number of autopsies of non-COVID-19 cases during the pandemic period was also investigated, and a significant decrease was observed compared with the incidence in the pre-pandemic period. The COVID-19 pandemic has affected not only the autopsies of COVID-19 cases but also the entire practice of pathological autopsies. It is necessary to establish a system that supports the implementation of pathological autopsy practices during the pandemic of an emerging infectious disease.


Subject(s)
COVID-19 , Humans , Autopsy , Pandemics , SARS-CoV-2 , Japan/epidemiology
3.
Biomed Eng Online ; 21(1): 62, 2022 Sep 05.
Article in English | MEDLINE | ID: covidwho-2009405

ABSTRACT

BACKGROUND: Aerosols and droplets are the transmission routes of many respiratory infectious diseases. The COVID-19 management guidance recommends against the use of nebulized inhalation therapy directly in the emergency room or in an ambulance to prevent possible viral transmission. The three-dimensional printing method was used to develop an aerosol inhalation treatment mask that can potentially prevent aerosol dispersion. We conducted this utility validation study to understand the practicability of this new nebulizer mask system. RESULTS: The fit test confirmed that the filter can efficiently remove small particles. The different locations of the mask had an excellent fit with a high pressure making a proper face seal usability. The full-face mask appeared to optimize filtration with pressure and is an example of materials that perform well for improvised respiratory protection using this design. The filtering effect test confirmed that the contamination of designated locations could be protected when using the mask with filters. As in the clinical safety test, a total of 18 participants (10 [55.6%] females; aged 33.1 ± 0.6 years) were included in the final analysis. There were no significant changes in SPO2, EtCO2, HR, SBP, DBP, and RR at the beginning, 20th, 40th, or 60th minutes of the test (all p >.05). The discomfort of wearing a mask increased slightly after time but remained within the tolerable range. The vision clarity score did not significantly change during the test. The mask also passed the breathability test. CONCLUSION: The results of our study showed that this mask performed adequately in the fit test, the filtering test, and the clinical safety test. The application of a full-face mask with antiviral properties, together with the newly designed shape of a respirator that respects the natural curves of a human face, will facilitate the production of personal protective equipment with a highly efficient filtration system. METHODS: We conducted three independent tests in this validation study: (1) a fit test to calculate the particle number concentration and its association with potential leakage; (2) a filtering effect test to verify the mask's ability to contain aerosol spread; and (3) a clinical safety test to examine the clinical safety, comfortableness, and visual clarity of the mask.


Subject(s)
COVID-19 , Respiratory Tract Infections , COVID-19/prevention & control , Female , Humans , Male , Masks , Respiratory Aerosols and Droplets , Respiratory Tract Infections/prevention & control , Ventilators, Mechanical
4.
GMS Hyg Infect Control ; 16: Doc27, 2021.
Article in English | MEDLINE | ID: covidwho-1470745

ABSTRACT

Introduction: To address the question as to which infection surveillance measures are used during the ongoing COVID-19 pandemic in Germany and how they differ from pre-existing approaches. Methods: In accordance with the systematic approach of a scoping review, a literature search was conducted in national and international medical literature databases using a search string. The search in the databases was limited to the period from 01.01.2000 to 15.11.2020 and has been subsequently completed by hand search until 08.03.2021. A hand search, even beyond 15.11.2020, seemed necessary and reasonable, since due to the dynamics of the ongoing COVID-19 pandemic, a large number of articles and regulations are being published very quickly at short notice. Results: The literature search resulted in the following number of hits in the databases listed below: PubMed: 165 articlesCochrane: 1 review and 35 studiesWeb of Science: 217 articlesRobert Koch Institute: 49 articles Thus, a total of 467 hits were identified, with a total of 124 hits being duplicates. From these, 138 articles were considered relevant to the COVID-19 infection surveillance situation in Germany based on established criteria. After reading the full texts, 92 articles and websites were ultimately included in the scoping review. Discussion: Many of the lessons learned from previous outbreaks seem to have been implemented in the infection surveillance measures during the ongoing COVID-19 pandemic in Germany. Most of the changes compared with previous measures were based on technological streamlining of existing procedures and changes and more inclusion of the population in different infection surveillance measures.

5.
Mol Imaging Radionucl Ther ; 29(2): 49-58, 2020 Apr 29.
Article in English | MEDLINE | ID: covidwho-191696

ABSTRACT

A viral pneumonia rapidly spread from Wuhan, China to all countries in late 2019. In February 2020, WHO named as Coronavirus Disease 2019 (COVID-19) and declared the pandemic on March 11, 2020. To prevent the spread of COVID-19, Ministry of Health of Republic of Turkey and international institutions have published documents defining hygiene rules. After the lung computerized tomography (CT) findings which are important in the diagnosis of COVID-19 are described, protection measures against infection were defined in radiology departments. There is no publication involving protection measures for diagnostic and therapeutic procedures in nuclear medicine (NM) (appointment, patient acceptance, imaging and treatment procedures, disinfection etc). There are two reports on CT findings suggesting COVID-19 in 18F-fluorodeoxyglucose positron emission tomography/CT scan. These lung findings detected in hybrid images will be helpful in the early diagnosis of pulmonary involvement. Infected cases may be asymptomatic and can unintentionally disseminate the virus to surrounding people. This advisory guide has been prepared to avoid infection risk in NM clinics. During the COVID-19 outbreak, staff must use proper personal protective equipment and patients should be evaluated as the elective case according to clinical status. A questionnaire should be made for COVID-19. In cancer cases requiring urgent treatment, radionuclide treatment (RNT) should be planned according to the COVID-19 test result. If the result is negative, RNT can be applied; but if not or if the symptoms are present, RNT must be postponed. Following imaging procedures, scanners and room surfaces should be cleaned by personnel with proper disinfection training.

SELECTION OF CITATIONS
SEARCH DETAIL